Cor-3500 System with Thermal Break
The frame and sash are 55 mm & 63 mm deep respectively both in windows as in doors. The average aluminium profile wall thickness is 1.5 mm. in windows and 1,7 mm. in doors.
The aluminium profiles are provided with a thermal break which is achieved by inserting 24 mm wide 6.6 polyamide isolation strips which are reinforced with 25% fibre glass.
Maximum glazing: 40 mm.
Maximum accoustic insulation Rw=46 dB
Transmittance
Uw from 1,1 (W/m²K)
Please consult typology, dimensions and glass
Classifications achieved at test centre*:
Air permeability according to EN 12207:2000 Class 4
Water tightness according to EN 12208:2000 Class E1200
Wind resistance according to EN 12210:2000 Class C5
* Test reference 1,20 x 1,20 m. 2 Sashes
Cor-60 System with Thermal Break
The frame and sash are 60 mm & 68 mm deep respectively both in windows as in doors. The average aluminium profile wall thickness is 1.6 mm in windows and doors.
The aluminium profiles are provided with a thermal break which is achieved by inserting 24 mm wide 6.6 polyamide isolation strips which are reinforced with 25% fibre glass.
Maximum glazing: 45 mm.
Maximum accoustic insulation Rw=48 dB
Transmittance
Uw from 1,0 (W/m²K)
Please consult typology, dimensions and glass
Classifications achieved at test centre*:
Air permeability according to EN 12207:2000 Class 4
Water tightness according to EN 12208:2000 Class E1200
Wind resistance according to EN 12210:2000 Class C5
* Test reference 1,20 x 1,16 m. 2 Sashes.
Cor-60 Hidden Sash System with thermal break
Hinged windows European channel composed of aluminum alloy profiles and heat treated 6063 T-5.
Possibility of all openings except the outer opening.
Frame and leaf have a depth of 60 mm. The average thickness of the aluminum is 1.6 mm.
The aluminum profiles are provided with thermal break obtained by inserting insulating tubular rods 24 mm polyamide 6.6. deep reinforced with 25% glass fiber.
Sealing system for EPDM triple.
Maximum glazing: 28 mm.
Maximum sound insulation Rw = 41 dB
Transmittance / Zones C.T.E. ;
UH from 1.3 (W / m².K)
Check type, size and glass
CTE- * Suitable for climatic zones: ABCDE α
* Depending on the transmittance of the glass.
Reached on a test bench * Categories:
Air permeability according to UNE-EN 12207: 2000 Class 4
Water tightness according to UNE-EN 12208: 2000 Class 9A
Wind resistance according to UNE-EN 12210: 2000 Class C5
* Reference test window x 1.16 m 1.13. 1 sheet
Cor-80 Industrial System with Thermal Break
Its great glazing capacity of up to 65mm allows for the use of energy efficient glazing and compositions of large thicknesses as well as double chambers that gives excellent thermal and acoustic performance (up to 46dB of noise protection) that translates in to maximum energy saving and total interior comfort. The performance achieved in the AEV test, has shown this window to have the best water tightness performance, air permeability and wind resistance in order to guarantee the greatest protection against the most adverse atmospheric agents. The simplicity in its assembly and less labour time, allows for a more industrialized fabrication resulting in a final saving of time and cost.
TECHNICAL DATA :
Accoustic insulation
Maximum glazing: 65 mm
Maximum accoustic insulation: Rw = 46 dB
Transmittance
Uw from 0,8 (W/m²K)
Please consult typology, dimensions and glass
Compliance Zones of RCCTE * I1 I2 I3
*Depending on the transmission coefficient thermal glass
Opening possibilities
Open in: Practicable, turn-tilt, parallel tilt, hinged
Open Out: Practicable, projecting-sliding
Sections / Profile thickness
Sections:
· Frame – 80 mm
· Sash – 88 mm
Profile thickness:
· Window – 1,5 mm
· Door – 1,7 mm
Polyamide strip length: 45 mm
Maximum dimensions / Maximum weight
Maximum dimensions:
Width (L) = 1.600 mm
Height (H) = 2.600 mm
*Single sash window, turn-tilt
Maximum weight/sash: 120 Kg
Please consult regarding maximum weight and dimensions for other opening types
Categories achieved at test centre
Air permeability (EN 12207:2000): Class 4
Water tightness (EN 12208:2000): Class E1950
Wind resistance (EN 12210:2000): Class C5
Reference test: 1, 23 m x 1,48 m. 2 sashes.
Finishes
· Possibility of dual colour
· Colour powder coating (RAL, mottled & rough)
· Wood effect powder coating
· Anti-bacterial powder coating
· Anodized
Cor-70 CC16 System with Thermal Break
Possiblity of straight and chamfered sashes and straight, chamfered or curved beads.
With its large glazing capacity of up to 58mm it presents to this system some excellent accoustic and thermal features allowing the use of large glazing thicknesses and energy efficiencies. There is the possibility of integrating hidden hinges accessories
TECHNICAL DATA :
Accoustic insulation
Maximum glazing: 58mm
Maximum accoustic insulation: Rw = 46 dB
Transmittance
Uw from 0,8 (W/m²K)
Please consult typology, dimensions and glass
Compliance Zones of RCCTE* I1 I2 I3
*Depending on the transmission coefficient thermal glass
Opening possibilities
Open In:
– Practicable, turn-tilt, folding, parallel tilt, hinged
Open Out:
– Practicable, projecting-sliding
Sections / Profile thickness
Sections:
· Frame – 70 mm
· Sash – 75 mm
Profile thickness:
· Window – 1,5 mm
· Door – 1,7 mm
Polyamide strip width: 35 mm
Maximum dimensions / Maximum weight
Maximum dimensions:
Width (L) = 1.600 mm
Height (H) = 2.800 mm
*Single sash window, turn-tilt
Maximum weight/sash: 150 Kg
Please consult regarding maximum weight and dimensions for other opening types
Categories achieved at test centre
Air permeability (EN 12207:2000): Class 4
Water tightness (EN 12208:2000): Class E1500
Wind resistance (EN 12210:2000): Class C5
Reference test: 1,23 m x 1,48 m. 2 sashes.
Finishes
· Possibility of dual colour
· Colour powder coating (RAL, mottled & rough)
· Wood effect powder coating
· Anti-bacterial powder coating
· Anodized
Cor-70 Hidden Sash System with Thermal Break
A 35 mm thermally broken area and the insertion of polyolefin sponge in the frame and sash allows it to reach values of up to 1,0W/m²K of transmission in the space and therefore maximising its energy efficiency. These high thermal performances are completed with an increased level of sound insulation that this system achieves thanks to the possibility of installing glazing units of up to 40mm in thickness. The classifications achieved in the AEV tests go to prove that the system has excellent water tightness, air permeability and wind resistance values in order to obtain increased protection against the most unfavourable weather conditions.
TECHNICAL DATA:
Accoustic insulation
Maximum glazing: 40 mm
Maximum acoustic insulation: Rw = 46 dB
Transmittance/Zones RCCTE
Uw from 1,0 (W/m²K)
Please consult typology, dimensions and glass
Compliance Zones of RCCTE* I1 I2 I3
* Depending on the heat transfer coefficient of the glass
Opening possibilities
Open In:
– Practicable 1 or 2 sashes
– Turn-tilt 1 or 2 sashes
Sections / Profile thickness
Sections:
· Frame – 70 mm
· Sash – 60 mm
Profile thickness:
· Window – 1,9 mm
Polyamide strip length: 35 mm
Maximum dimensions / Maximum weight
Maximum dimensions:
Width (L) = 1.300 mm
Height (H) = 2.400 mm
*Single sash window, turn-tilt
Maximum weight/sash: 120 Kg
Please consult regarding maximum weight and dimensions for other opening types
Categories achieved at test centre
Air permeability (EN 12207:2000): Class 4
Water tightness (EN 12208:2000): Class E1650
Wind resistance (EN 12210:2000): Class C5
Reference test: 1, 23 m x 1,48 m. 2 sashes.
Finishes
· Possibility of dual colour
· Colour powder coating (RAL, mottled & rough)
· Wood effect powder coating
· Anti-bacterial powder coating
· Anodized