Millenium FR Door System with Thermal Break

Este nuevo sistema de puerta cortafuegos de aluminio con clasificación de resistencia al fuego clase EI60
View full description

  • Product information

This new fire resistant door system that has a fire resistance classification of EI260, resolves the security requirements in case of fire, allowing for the compartimentalization in fire sectors in the building and the evacuation of the users.

Comprising of 80mm section straight line coplanar profiles, 2.2mm thick and a 35mm thermal breaking zone, it offers a 60 minutes fire resistance time thanks to the utilisation of retardant insulation materials that do not combust in the profile chambers as well as intumescentant gaskets that dilate and bio-soluble paper in the glass area.

With a frame transmission value from 1.4 W/m²K, it reaches unbeatable thermal features and with its large glazing capacity having a free space of 56mm, it guarantees a maximum accoustic insulation.

Possibility of joining with fixed lights, incorporation of opening gearing with anti-panic function, automatic door closers and handles/hinges officially approved in the sectoring of fires.

TECHNICAL DATA :

Accoustic insulation

Maximum glazing: 48 mm

Maximum accoustic insulation: Rw = 38 dB

Transmittance

Uw from 1,4 (W/m²K)

Please consult typology, dimensions and glass

Compliance Zones of RCCTE* I1 I2 I3
*Depending on the transmission coefficient thermal glass

Opening possibilities

Open In: Practicable 1 & 2 sashes

Open Out: Practicable1 & 2 sashes

apertura_1

Sections / Profile thickness

Sections:
· Frame – 80 mm
· Sash – 80 mm

Profile thickness:
· Door – 2,2 mm

Polyamide strip width: 35 mm

Maximum dimensions / Maximum weight

Maximum dimensions:
Width (L) = 1.500 mm
Height (H) = 2.600 mm
*Single sash window, turn-tilt

Maximum weight/sash: 240 Kg

Please consult regarding maximum weight and dimensions for other opening types

Categories achieved at test centre

FIRE RESISTANCE AND SMOKE CONTROL

Test carried out according to norms EN 1364-1:2000 and EN 1634-1:2010: Class EI 2 60 – C5

Classification according to norm EN 13501-2:2009 A1:2010 (C5= 200.000 test cycles)

Door test reference: 1,35 m x 2,35 m. 1 sash. Glass EI60 single glazed 23 to 25 mm

Finishes

· Possibility of dual colour

· Colour powder coating (RAL, mottled & rough)

· Wood effect powder coating

· Anti-bacterial powder coating

· Anodized